Volatilization
Analytes with high vapor pressures, such as volatile organics and dissolved gases (e.g., HCN, SO2) can easily be lost by evaporation. Filling sample containers to the brim so that they contain no empty space (headspace) is the most common method of minimizing volatilization. Solid samples can be topped with a liquid to eliminate headspace. The volatiles cannot equilibrate between the sample and the vapor phase (air) at the top of the container. The samples are often held at low temperature (4º C) to lower the vapor pressure. Agitation during sample handling should also be avoided. Freezing liquid samples causes phase separation and is not recommended.
|
|